Install Instructions
Extra Touches That Mean Extra Efficiency
1. Butt ALL seams. Use only reflective
tape recommended by the manufacturer for
insulation applications. NEVER USE DUCT
TAPE!
2. Make sure tape and insulation are clean,
dry and applied according to tape
manufacturer’s recommendations. Apply
tape evenly over seams using a tape width
that is appropriate to the job. Usually, the
wider the tape, the easier it is to install.
3. Use a squeegee or flat edge to press
against the tape to ensure the best
adhesion. Keep insulation as smooth as
possible. When taping, it helps to work from
the middle out to the ends. Squeegee the
tape with a flat edge to ensure a tight seal.
4. Always follow the tape manufacturer’s
recommendations on storage and use.
5. Manufacturer recommends using an
acrylic based adhesive tape, wherever
moisture or condensation is a concern.
Small punctures, large rips or tears can be
repaired or patched with pressure sensitive
reflective tape.
6
is a registered trademark of Innovative Energy, Inc.
800-776-3645
www.insul.net info@insul.net
Connect with us on:
Friction fit
AstroShield & AstroArmour
around lighting fixtures, exhaust fans,
motors, vents, or other equipment
extending onto the roof. Strictly follow
manufacturer’s recommendations on
covering or coming into contact with their
fixtures.
Eliminate cold spots by filling cracks around
doors or window framing. Where possible,
bow
AstroShield & AstroArmour
into
openings. Use a closed cell foam product
to fill small cracks. Follow manufacturer’s
recommendations for proper use.
TAPING INSTRUCTIONS
General guide to application,
appearance and performance
A. WARNING!
Metalized fi lm is an excellent
conductor of electricity. In both new
construction and retrofit applications it is
important to make sure there are no “live”,
bare wires in the work area that could come
in contact with
AstroShield & AstroArmour
or installers during or after installation. Use
caution around junction boxes and electrical
fixtures. Have a qualified electrician examine
area for safety
BEFORE
INSTALLATION.
B.
AstroShield works best with an air space on
each side of the insulation.
C.
Taping seams is not always necessary for
good performance. In buildings where
moisture or condensation in not a concern,
overlapping edges or installing them behind
girts or purlins is often all that is required.
Animal confinement buildings, food or seed,
or vegetable storage structures generally
give off moisture to the air that can cause
condensation in some climates. Careful
taping of all seams and covering of all
building truss members in direct contact with
the building metal skin will improve
maximum building envelope performance.
AstroShield & AstroArmour
properly
installed and taped in a building with
adequate ventilation, is your best protection
against condensation problems.
D.
Do not paint AstroShield & AstroArmour's
surface or allow it to be coated with a liquid.
Metalized film will not reflect heat if painted.
E.
Attach to wood with staples at least 1/4” in
length; attach to metal with self-tapping
screws at least 1/4” in length.
F.
Store rolls in a dry area, out of direct
sunlight and in plastic bags until ready for
use.
G.
Do not install
AstroShield & AstroArmour
on top of existing mineral fiber insulation,
cellulose or rock-wool in attics or roofs.
However, these same products can be
installed on top of
AstroShield &
AstroArmour
.
For technical information on specific
applications, contact your nearest
AstroShield & AstroArmour dealer or call
1-800-776-3645.