Install Instructions

2
4. When securing bottom, staple or tape insulation to
the sill plate or a furring strip secured to the floor.
5. Position first length at corner, wrapping around
the corner and fasten with self-tapping screws or
with reflective tape, sufficient to hold in place.
NOTE: If the AstroShield product you are installing on walls is
one of the AstroShield 'White' products, and the reflective
surface is facing toward the outside, installation must include a
method of insuring a 1" airspace between Astroshield and the
metal siding.
3. Cut a second length and position next to the first
length. Butt sides evenly together or slightly overlap.
Tape all seams following the instructions on page 6.
Measure and cut lengths as in Step 1. Attach to the
inside of the top of the wall plate as in Step 2. Begin
hanging and securing subsequent strips as in Step 3.
Leave approximately 1” airspace between wall and
insulation. Continue installation per Step 4 and 5,
following taping instructions on page 6.
RETROFIT APPLICATION
NEW CONSTRUCTION
AstroShield & AstroArmour
can be installed in
sidewalls, either running from the top wall plate down
to the foundation or running horizontal along the
structure’s frame, prior to the installation of the metal
sheeting. Page 2 of this manual describes vertical
installation; page 3, horizontal.
1. Measure the length to be applied, then cut a similar
length of
AstroShield & AstroArmour. A dd a n in ch o r
t wo t o assure complete coverage at top and bottom.
2. At corners, wrap
AstroShield & AstroArmour
a round the corner and continue vertical installation as
described in the previous steps. Attach metal sheeting
directly over insulation in the conventional manner.
Pre-Engineered Metal Buildings:
Vertical Installation of AstroShield/AstroArmour in Walls