Instruction manual

Table Of Contents
Chapter 4 MAIN SPECIFICATIONS
73
4.7 Concerning the audio level meter
The audio level meter indicates the level as follows.
Audio standards: BTA S-006B and SMPTE 272M-A
ch**
-48 -42 -36 -30 -24 -20 -18 -12 -6 0 (Unit: dB)
or less or less or less or less or less or less or less or less or less or less
NOTE
The level is displayed in the left-most cell when audio signals with a level of
less than -48 dB are supplied. This makes it possible to visually identify
whether sound is input.
The audio level meter is displayed only when SDI signals are selected. When
sync signals have been set as the external reference, the level meter may
malfunction although this rarely happens.
In the following cases, the audio data cannot be sampled by this monitor.
With the HD format:
A
DF for the audio auxiliary data fails to come immediately after the CRC data.
With the SD format:
A
DF for the audio auxiliary data fails to come immediately after EAV.