Instruction manual

Table Of Contents
Chapter 3 OPERATION
43
[ Description of operations ]
Switch Description of function
FUNC switch Use this to switch the display to the VECTOR mode setting screen.
(Refer to section 3.4.7.2.)
When the gain setting is fixed
Fix ×1 / ×5
No function.
When the gain setting is variable
Val ×*.**
Turn the dial to set the magnification rate of the
gain.
(Variable range: 0.03 to 7.97)
Turning the adjustment dial
When line select is ON Turn the dial to increment or decrement the
lines. The line select ON/OFF and line settings
are linked in the WAVEFORM mode and
VECTOR mode.
When the gain setting is fixed
Fix ×1 / ×5
No function.
When the gain setting is variable
Val ×*.**
The gain is an integral value after the decimal
places have been rounded down (with a figure
or 4 or below) or rounded up (with a figure of 5
or above). (All values below 0.49 are set to
0.03; similarly, all values above 7.00 are set to
7.00.)
If the gain magnification rate is an integer, it is
increased in 1.00 increments, and when 7.00 is
reached, it is returned to 1.00.
Pressing the adjustment dial
When line select is ON Use the switch to select the field. (Field
switching applies only with the interlacing or
segmented frame format.)
F1 switch
GAIN Fix ×1 /
GAIN ×5 /
GAIN Val ×*.**
Use this switch to set line select to OFF and to switch between the fixed (Fix ×1 / ×5) and
variable (×*.**) gain setting.
In the Fix ×1 status, the loci between the pixels are interpolated for the display; in other
statuses, only the points are displayed.
F2 switch No function.
F3 switch No function.
F4 switch No function.
F5 switch
LineSelect
Use this to set line select to ON or OFF. When line select is ON, the gain setting display
is fixed (Fix ×1).