Instruction manual
  WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 
49
CHAPTER 4 MAIN SPECIFICATIONS 
4.1 Input formats 
Format 
Frame 
Rate 
(Hz) 
Active 
Line 
per 
Frame
Total 
Line 
Per 
Frame
Line 
Frequency
(kHz) 
Samples 
per 
Active 
Line 
Samples 
per 
Total 
Line 
Scanning
*1 
*2 
1035i/59.94 30/1.001 1035 1125 33.72  1920  2200  i 
1035i/60 
1035i/60 30  1035 1125 33.75 1920 2200  i 
<1> 
1080i/59.94 
1080sF/29.97 
30/1.001 1080  1125  33.72  1920  2200 
i 
sF 
1080i/60 
1080i/60 
1080sF/30 
30 1080 1125 33.75 1920 2200 
i 
sF 
<1> 
<2> 
<1> 
<2> 
1080p/29.97 30/1.001 1080  1125 33.72  1920  2200  p 
1080p/30 
1080p/30 30  1080 1125 33.75 1920 2200  p 
<2> 
1080sF/25 
(1080i/50) 
1080sF/25 
1080i/50 
25 1080 1125 28.13 1920 2640 
sF 
i 
<2> 
1080p/25 1080p/25  25  1080  1125  28.13  1920  2640  p  <2> 
1080sF/23.98 24/1.001 1080  1125  26.97  1920  2750  sF 
1080sF/24 
1080sF/24 24  1080 1125 27.00  1920  2750  sF 
<2> 
1080p/23.98 24/1.001 1080  1125 26.97  1920  2750  p 
1080p/24 
1080p/24 24  1080 1125 27.00 1920 2750  p 
<2> 
720p/59.94 60/1.001 720  750 44.96  1280  1650  p 
720p/60 
720p/60 60  720 750 45.00 1280 1650  p 
<3> 
720p/50 720p/50 50  720  750  36.00  1280  1980  p  <3> 
720p/29.97 30/1.001 720  750 22.48  1280  3300  p 
720p/30 
720p/30 30  720 750 22.50 1280 3300  p 
<3> 
720p/25 720p/25 25  720  750  18.75  1280  3960  p  <3> 
720p/23.98 24/1.001 720  750 17.98  1280  4125  p 
720p/24 
720p/24 24  720 750 18.00 1280 4125  p 
<3> 
*1:  Scanning abbreviations 
i = Interlace 
sF = Segmented Frame 
p = Progressive 
*2: Standards 
<1> BTA S-001B, S-002B, S-004B complied with 
<2> SMPTE 274M complied with 
<3> SMPTE 296M complied with 