Instruction manual

WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL
35
3.3.4.6 WAVEFORM setting screen
<<Functions>>
The waveforms can be displayed, and the following settings can be performed.
Waveform display YPbPr/GBR switching
V ancillary (Wave), H blanking switching
Scale switching
LPF (Wave) switching
<<Screen>>
[Description of operations]
Switch Description of function
FUNC switch Press this to return the display to the function screen.
(Refer to section 3.3.4.1)
Adjustment dial (Not used)
Setting switch (Not used)
F1 switch
Waveform YPbPr/GBR
Press this to switch between YPbPr and GBR for the waveform
display.
F2 switch
V anc ON/OFF
Press this to set V ancillary to ON or OFF.
This takes effect only when the WAVEFORM mode is established.
F3 switch
H Blank ON/OFF
Press this to set H blanking to ON or OFF.
F4 switch
Scale %/V
Press this to switch the scale units between % and V.
F5 switch
LPF(Wave) ON/OFF
Press this to set the low-pass filter (Wave) to ON or OFF.
This takes effect only when the WAVEFORM mode is established.
YCRCE:000000000 PCRCE:000000000 (LAST:00:00:00/TIME:00:00:00
Input SDI A
Format AUTO
(1080i
60.00)
Int
YPbPr
Parade
1H Mx1
G x1.00
Waveform
YPbPr
GBR
V anc(Wave)
ON
OFF
H Blank
ON
OFF
Scale
%
V
VITC:--:--:--:--
LPF(Wave)
ON
OFF
dT 8.00µs
d% 20.00%
Field 1
Line(Field) 0001
Line(Frame) 0001
WAVEFORM MONITO
R
HD LCD
WM-3004
INPUT
F1
DISPLAY
F2
OVERLAY
F3
FREEZE
F4
FUNC
F5
LOCK
OFF
ON
POWER
|
PICTURE
MENU
STATUS
2
1
3
1
2
WAVE
V
ECTO
R
AUDIO