Instruction manual
  WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 
34
3.3.4.5  CURSOR setting screen 
<<Functions>> 
The waveforms can be displayed, and the following setting can be performed. 
• H and V cursor display and difference display (mV, µs) 
<<Screen>> 
 [Description of operations] 
Switch  Description of function 
FUNC switch 
Press this to return the display to the function screen. 
(Refer to section 3.3.4.1) 
Adjustment dial  Use this to move the cursor horizontally or vertically. 
Setting switch  (Not used) 
F1 switch 
 H 
Press this to set the H cursor to ON or OFF. 
F2 switch 
 V 
Press this to set the V cursor to ON or OFF. 
F3 switch 
 MOVE BASE/OFFSET/TRACK 
Press this to select the cursor (BASE, OFFSET or TRACK) to be 
moved. 
F4 switch 
 H/V 
Press this to select the cursor (H or V) to be moved. 
F5 switch  (Not used) 
YCRCE:000000000 PCRCE:000000000 (LAST:00:00:00/TIME:00:00:00)
Input SDI A 
Format AUTO 
 (1080i 
 60.00) 
Int 
 YPbPr 
 Parade   
 1H   Mx1 
 G x1.00 
 H 
 V 
dT 8.00µs
d% 20.00%
 MOVE    
 BASE    
   OFFSET 
   TRACK 
 H/V 
 H 
 V 
VITC:--:--:--:-- 
 Field 1    
Line(Field)  0001
Line(Frame) 0001
WAVEFORM MONITO
R
HD LCD
WM-3004
INPUT 
F1
DISPLAY 
F2
OVERLAY 
F3
FREEZE
F4
FUNC
F5
LOCK
OFF
ON
POWE
R
|
○
PICTURE
MENU
STATUS
2
1
3
1
2
WAVE
V
ECTO
R
AUDIO