Instruction manual

WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL
29
3.3.4.2 DISPLAY setting screen
<<Functions>>
The waveforms can be displayed, and the following settings can be performed.
Switching between parade display (side-by-side display) and overlay display
(superimposed display) for the waveforms
Line select function (with 1H, 2H)
<<Screen>>
[Description of operations]
Switch Description of function
FUNC switch
Press this to return the display to the function screen.
(Refer to section 3.3.4.1)
F1 switch
Parade/Overlay
Press this to switch between parade display (side-by-side display) and
overlay display (superimposed display) for the waveforms.
F2 switch
Y
Press this to set Y/G to ON or OFF.
F3 switch
Pb(Cb)
Press this to set Pb/B to ON or OFF.
F4 switch
Pr(Cr)
Press this to set Pr/R to ON or OFF.
F5 switch
LineSelect
Press this to set line select to ON or OFF.
When line select is ON, the lines are incremented or decremented using
the adjustment dial, and the field is switched using the setting switch.
(This applies with 1H or 2H only; field switching applies only with
interlacing or segmented frame format.)
WAVEFORM MONITO
R
HD LCD
WM-3004
INPUT
F1
DISPLAY
F2
OVERLAY
F3
FREEZE
F4
FUNC
F5
LOCK
OFF
ON
POWE
R
|
PICTURE
MENU
STATUS
2
1
3
1
2
WAVE
V
ECTO
R
AUDIO
YCRCE:000000000 PCRCE:000000000 (LAST:00:00:00/TIME:00:00:00
Input SDI A
Format AUTO
(1080i
60.00)
Int
YPbPr
Parade
1H Mx1
G x1.00
Parade
Overlay
Y
Pb(Cb)
Pr(Cr)
LineSelect
dT 8.00µs
d% 20.00%
VITC:--:--:--:--
Field 1
Line(Field) 0001
Line(Frame) 0001