Instruction manual
  WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 
16
[Description of operations] 
Switch  Description of function 
INPUT switch  This switch is used to select the SDI A or SDI B input signals.    When 
it is held down (for more than one second), analog signals are input.   
If the freeze status is established at this time, it is released. 
DISPLAY switch  This switch is used to set whether the information is to be partially 
displayed on the screen or not displayed at all.    When it is held down 
(for more than one second), the top and bottom of the screen are 
inverted. 
OVERLAY switch  This switch is used to perform the picture overlay settings.    In the 
PICTURE1, PICTURE2 or PICTURE3 mode, it has no effect since a 
picture is always displayed.    When it is held down (for more than 1 
second), the color setting screen appears.    (The color setting items 
differ according to the mode selected.) 
FREEZE switch  This switch is used to select freeze or update. 
Freeze is released by switching the input signals or format.    Bear in 
mind that if the input signals are cut off or their format has been 
changed in the freeze status, the correct data will not be output. 
CRC errors are counted even while the freeze status is established. 
FUNC switch  This switch is used to select the function switches (switches F1 to F5).
LOCK switch  All key operations are canceled, and the values for the setting items in 
section 4.6 are saved. 
  Wait  appears at the bottom right of the 
screen while the settings are being saved, and upon completion of the 
saving process,  PANEL LOCK  appears.    Do not turn off the power 
while the setting saving process is in progress. 
The saved settings are loaded and established when the power is 
turned on. 