Instruction manual

WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL
16
[Description of operations]
Switch Description of function
INPUT switch This switch is used to select the SDI A or SDI B input signals. When
it is held down (for more than one second), analog signals are input.
If the freeze status is established at this time, it is released.
DISPLAY switch This switch is used to set whether the information is to be partially
displayed on the screen or not displayed at all. When it is held down
(for more than one second), the top and bottom of the screen are
inverted.
OVERLAY switch This switch is used to perform the picture overlay settings. In the
PICTURE1, PICTURE2 or PICTURE3 mode, it has no effect since a
picture is always displayed. When it is held down (for more than 1
second), the color setting screen appears. (The color setting items
differ according to the mode selected.)
FREEZE switch This switch is used to select freeze or update.
Freeze is released by switching the input signals or format. Bear in
mind that if the input signals are cut off or their format has been
changed in the freeze status, the correct data will not be output.
CRC errors are counted even while the freeze status is established.
FUNC switch This switch is used to select the function switches (switches F1 to F5).
LOCK switch All key operations are canceled, and the values for the setting items in
section 4.6 are saved.
Wait appears at the bottom right of the
screen while the settings are being saved, and upon completion of the
saving process, PANEL LOCK appears. Do not turn off the power
while the setting saving process is in progress.
The saved settings are loaded and established when the power is
turned on.