Instruction manual

WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL
11
*1: Power socket (no. <1>)
Pin No. Function
1 GND
2 NC
3 NC
4 DC IN (10-18V)
*2: TALLY connector (no. <9>)
Pin No. Function
1 GND
2 TALLY2 (green)
3 NC (reserved) (Note)
4 NC (reserved) (Note)
5 NC (reserved) (Note)
6 GND
7 TALLY1 (red)
8 NC (reserved) (Note)
9 GND
When GND and pin 2 are shorted, the green tally lamp lights; when GND and pin 7 are shorted, the
red tally lamp lights.
(Note) Do not connect anything to the pins marked NC (reserved). Doing so may cause
malfunctioning.
*3: Termination selector switch (no. <10>)
As shown in the figure above, the initial setting positions starting with the top one first are left (Y 75
termination), left (Pb 75
termination) and left (Pr 75 termination).
Switch Setting
Left Right
Y
Y 75 termination
No Y termination
PB
PB 75 termination
No PB termination
PR
PR 75 termination
No PR termination
1
5
6
9
Y
HIGH
75
PB
PR
1
2
3
4