Instruction manual
  WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 
11
*1:  Power socket (no. <1>) 
Pin No. Function 
1 GND 
2 NC 
3 NC 
4  DC IN (10-18V) 
*2:  TALLY connector (no. <9>) 
Pin No. Function 
1 GND 
2 TALLY2 (green) 
3  NC (reserved) (Note) 
4  NC (reserved) (Note) 
5  NC (reserved) (Note) 
6 GND 
7 TALLY1 (red) 
8  NC (reserved) (Note) 
9 GND 
When GND and pin 2 are shorted, the green tally lamp lights; when GND and pin 7 are shorted, the 
red tally lamp lights. 
(Note)  Do not connect anything to the pins marked NC (reserved). Doing so may cause 
malfunctioning. 
*3:  Termination selector switch (no. <10>) 
As shown in the figure above, the initial setting positions starting with the top one first are left (Y 75Ω 
termination), left (Pb 75
Ω termination) and left (Pr 75Ω termination). 
Switch  Setting 
 Left  Right 
Y 
Y 75Ω termination 
No Y termination 
PB 
PB 75Ω termination 
No PB termination 
PR 
PR 75Ω termination 
No PR termination 
1 
5 
6 
9 
Y
HIGH
75Ω 
PB 
PR 
1 
2 
3 
4 