WM-3004HD HD LCD Waveform Monitor Instruction Manual August 25, 2003 Ver.1.00 ASTRODESIGN, Inc.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL CONTENTS INTRODUCTION・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・3 SAFETY PRECAUTIONS ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・4 CHAPTER 1 CONCERNING THE WM-3004 ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・7 CHAPTER 2 PARTS AND THEIR FUNCTIONS ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・8 2.1 WM-3004 front panel view and parts ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・8 2.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL INTRODUCTION Thank you very much for purchasing this model WM-3004 HD LCD waveform monitor. This manual contains details on the operation procedures to be followed when the WM-3004 is used, the checkpoints and precautions to be observed, and so on. Improper handling may result in malfunctioning. Before using the WM-3004, please read through these instructions to ensure that you will operate the monitor correctly.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL SAFETY PRECAUTIONS WARNING Concerning the monitor Do not subject the monitor to strong shocks or throw it around. Doing so may cause the liquid crystal to leak and/or the monitor to malfunction, rupture, generate heat and cause a fire. Do not use the monitor wherever there is a risk of ignition or explosions. Do not place the monitor inside a microwave oven or other heating or cooking appliance or pressure vessel.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL CAUTION Concerning the power supply Use a supply voltage within the range of 10V-18V DC for the monitor. Do not turn the power back on immediately after having turned it off. malfunctioning. Doing so can cause Concerning the liquid crystal Due to the nature of liquid crystal, some picture elements may be missing (bright spots, dark spots, etc.) at times. Do not touch any liquid crystal which has leaked from the liquid crystal panel.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL Concerning installation and operation locations Installing the monitor in the following kinds of locations may cause malfunctioning and/or accidents.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL CHAPTER 1 CONCERNING THE WM-3004 The WM-3004 is a compact, lightweight and portable LCD waveform monitor which comes in handy for monitoring the pictures being shot during live broadcasts, on location or in studios, etc. The camera battery is supported as the power supply so that pictures, waveforms and sound can be checked even in locations where difficulties have been encountered in the past in carrying in equipment.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL CHAPTER 2 PARTS AND THEIR FUNCTIONS 2.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL Front panel parts and their functions Number Part <1> Power switch/LED <2> LOCK switch/LED <3> Mode switch <4> <5> <6> <7> Adjustment dial Setting switch Headphone jack Liquid crystal display <8> TALLY 1 <9> TALLY 2 <10> 1/4-20UNC threaded hole <11> INPUT switch <12> DISPLAY switch <13> OVERLAY switch <14> FREEZE switch <15> FUNC switch <16> F1 switch <17> F2 switch <18> F3 switch <19> F4 switch <20> F5 switch Descrip
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 2.2 WM-3004 rear panel view and parts WM-3004 rear panel view <4> <5> <6> <2> <3> <7> <9> <1> <10> <8> Names of rear panel parts Number <1> <2> <3> <4> <5> <6> <7> <8> <9> <10> Part Description of function Cannon connector, DC power input socket (GND: pin 1; DC IN: Power socket (*1) pin 4). SDI IN Ach HD-SDI signal input connector. SDI IN Bch HD-SDI signal input connector.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL *1: Power socket (no. <1>) 1 4 2 Pin No. 1 2 3 4 Function GND NC NC DC IN (10-18V) Pin No. 1 2 3 4 5 6 7 8 9 Function GND TALLY2 (green) NC (reserved) (Note) NC (reserved) (Note) NC (reserved) (Note) GND TALLY1 (red) NC (reserved) (Note) GND 3 *2: TALLY connector (no. <9>) 1 5 6 9 When GND and pin 2 are shorted, the green tally lamp lights; when GND and pin 7 are shorted, the red tally lamp lights.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL CHAPTER 3 OPERATION 3.1 Connections This section describes how to connect the WM-3004. (1) Connecting the power supply Connect the Cannon connector of the AC/DC adapter to the WM-3004's power socket. Check the shape of the connector and socket before use. (2) Connecting the input signals When SDI signals are to be input: When SDI signals are to be input, use BNC coaxial cables to make the connections to the SDI IN connectors.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3 Operation and how to use the switches This section describes the displays which appear on the WM-3004 screen and the setting methods involved. <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL [Description of screen displays] Item Input Format (Reference) NoSignal VITC YCRCE PCRCE LAST TIME Freeze Filter Mono FRC Description Displayed here is the input channel (SDI A, SDI B or Analog) which has been selected by the INPUT switch. The selected format is displayed here. Indicated within the parentheses on the line below are the input signal format and field (or frame) frequency.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL Item G B R (Marker) Y-Gamma Bright Contrast Pb(Cb) Pr(Cr) YPbPr / GBR Parade / Overlay 1H / 2H / 1F / 2F M x1 / x2 / x4 G x*.** dT d% / dV Field 1 / Field 2 Line (Field) Line (Frame) Sample x 1.00 Volume L:xCH R:xCH Information Marker Scale Waveform Cursor Vector Status Description This indicates whether the input video green (G) signal is to be displayed. This indicates whether the input video blue (B) signal is to be displayed.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL [Description of operations] Switch INPUT switch DISPLAY switch OVERLAY switch FREEZE switch FUNC switch LOCK switch Description of function This switch is used to select the SDI A or SDI B input signals. When it is held down (for more than one second), analog signals are input. If the freeze status is established at this time, it is released.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.1 PICTURE1 mode 3.3.1.1 Picture adjustments 1 screen <> The input images can be displayed, and the following video adjustments can be undertaken.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL Input SDI A Filter ON Format AUTO Mono OFF 60.00) FRC OFF (1080i G B R Int FRAME CENTER 4:3 13:9 14:9 2.35:1 1.85:1 1.66:1 Y-Gamma 1.000 Bright 0.00% Contrast 100.0% Pb(Cb) 100.0% Pr(Cr) 100.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL [Description of operations] Switch FUNC switch F1 switch Bright F2 switch Contrast F3 switch Chroma F4 switch Pb(Cb) F5 switch Pr(Cr) Description of function This switches the display to the picture adjustment 2 screen. (Refer to section 3.3.1.2) Press this to adjust the brightness using the adjustment dial. Refer to section 4.5. (Variable range: -50.00% to +50.00%) Press this to adjust the contrast using the adjustment dial. (Variable range: 0.0%-200.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.1.2 Picture adjustments 2 screen <> The input images can be displayed, and the following video adjustment can be undertaken. • Y gamma <> Input SDI A Format AUTO (1080i 60.00) Int Filter ON Mono OFF FRC OFF G B R FRAME CENTER 4:3 13:9 14:9 2.35:1 1.85:1 1.66:1 Y-Gamma 1.000 Bright 0.00% Contrast 100.0% Pb(Cb) 100.0% Pr(Cr) 100.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.1.3 Color setting screen <> When the OVERLAY switch is held down in the PICTURE1 mode, the input images can be displayed, and the following settings can be performed. • Character color • Marker color << screen>> Information Marker Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 22
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.2 PICTURE2 mode 3.3.2.1 Picture settings 1 screen <> The input images can be displayed, and the following settings can be performed. • Filter • Monochrome • FRC • Markers <> Input SDI A Format AUTO 60.00) (1080i Int Filter ON Mono OFF FRC OFF G B R FRAME CENTER 4:3 13:9 14:9 2.35:1 1.85:1 1.66:1 Y-Gamma 1.000 Bright 0.00% Contrast 100.0% Pb(Cb) 100.0% Pr(Cr) 100.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.2.2 Picture settings 2 screen <> The input images can be displayed, and the following settings can be performed. • Selection of display or non-display for green, blue and red signals of the displayed pictures. (This affects only the picture display.) <> Input SDI A Format AUTO 60.00) (1080i Int Filter ON Mono OFF FRC OFF G B R FRAME CENTER 4:3 13:9 14:9 2.35:1 1.85:1 1.66:1 Y-Gamma 1.000 Bright 0.00% Contrast 100.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.2.3 Color setting screen <> When the OVERLAY switch is held down in the PICTURE2 mode, the input pictures can be displayed, and the following settings can be performed. • Character color • Marker color <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.3 PICTURE3 mode 3.3.3.1 Regular screen <> The input pictures are displayed, and all displays with the exception of NoSignal , the time code (VITC), Freeze and the markers are cleared. Apart from displaying the time code (VITC), the functions in the PICTURE3 mode are identical to the PICTURE2 mode functions.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.3.2 Color setting screen <> When the OVERLAY switch is held down in the PICTURE3 mode, the input pictures can be displayed, and the following settings can be performed.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.4 WAVEFORM mode 3.3.4.1 Function screen <> The waveforms are displayed on this screen. <> Input SDI A Format AUTO 60.00) (1080i Int YPbPr Parade 1H Mx1 G x1.00 dT 8.00µs d% 20.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.4.2 DISPLAY setting screen <> The waveforms can be displayed, and the following settings can be performed. • Switching between parade display (side-by-side display) and overlay display (superimposed display) for the waveforms • Line select function (with 1H, 2H) <> Input SDI A Format AUTO (1080i 60.00) Int YPbPr Parade 1H Mx1 G x1.00 dT 8.00µs d% 20.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.4.3 SWEEP setting screen <> The waveforms can be displayed, and the following settings can be performed. • 1H, 2H, 1F or 2F display switching • Line select function (with 1H or 2H) <> Input SDI A Format AUTO (1080i 60.00) Int YPbPr Parade 1H Mx1 G x1.00 dT 8.00µs d% 20.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL [Description of operations] Switch FUNC switch F1 switch 1H F2 switch 2H F3 switch 1F F4 switch 2F F5 switch LineSelect Description of function Press this to return the display to the function screen. (Refer to section 3.3.4.1) 1H 2H (with interlacing or segmented frame format) In the line select OFF status, the odd-numbered fields are displayed on the left side, and the even-numbered fields are displayed on the right side.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.4.4 GAIN/MAG setting screen <> The waveforms can be displayed, and the following settings can be performed. • Gain (0.03X to 7.97X), MAG (1X, 2X or 4X) setting • Scroll functions <> Input SDI A Format AUTO 60.00) (1080i Int YPbPr Parade 1H Mx1 G x1.00 dT 8.00µs d% 20.00% Field 1 Line(Field) 0001 Line(Frame) 0001 INPUT GAIN ×1.00 MAG ×1 ×2 ×4 F1 DISPLAY F2 PICTURE 1 2 3 MENU OVERLAY 1 2 F3 AUDIO Adj.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL [Description of operations] Switch FUNC switch Adjustment dial Setting switch F1 switch GAIN x*.** F2 switch MAG x1/x2/x4 F3 switch RENC GainVal/Scroll F4 switch UP DOWN/LEFT RIGHT F5 switch Description of function Press this to return the display to the function screen. (Refer to section 3.3.4.1) When setting the gain Use the dial to set the magnification rate of the gain. (Variable range: GainVal 0.03 to 7.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.4.5 CURSOR setting screen <> The waveforms can be displayed, and the following setting can be performed. • H and V cursor display and difference display (mV, µs) <> Input SDI A Format AUTO (1080i 60.00) Int YPbPr Parade 1H Mx1 G x1.00 dT 8.00µs d% 20.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.4.6 WAVEFORM setting screen <> The waveforms can be displayed, and the following settings can be performed. • • • • Waveform display YPbPr/GBR switching V ancillary (Wave), H blanking switching Scale switching LPF (Wave) switching <> Input SDI A Format AUTO (1080i 60.00) Int YPbPr Parade 1H Mx1 G x1.00 dT 8.00µs d% 20.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.4.7 Color setting screen <> When the OVERLAY switch is held down in the WAVEFORM mode, the following settings can be performed. • Character color • Scale color • Waveform color and brightness • Cursor color <> Input SDI A Format AUTO (1080i 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.5 VECTOR mode 3.3.5.1 Normal screen <> The signals on the vectorscope can be displayed, and the following settings can be performed. • • Increase of black, white levels Line selection function <> Input SDI A ×1.00 Format AUTO 60.00) (1080i Int Field 1 Line(Field) 0001 Line(Frame) 0001 INPUT F1 GAIN Fix x1 Val x1.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL [Description of operations] Switch FUNC switch Adjustment dial Setting switch F1 switch GAIN Fix x1/Val x*.** F2 switch F3 switch F4 switch F5 switch LineSelect Description of function This switches the display to the VECTOR mode setting screen. (Refer to section 3.3.5.2) When the gain setting is (Not used) fixed Fix x1 When the gain setting Use the dial to set the magnification rate of the gain. (Variable range: 0.03 can be varied Val x*.** to 7.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.5.2 VECTOR mode setting screen <> The signals on the vectorscope can be displayed, and the following settings can be performed. • V ancillary (Vect) switching • Scale switching • LPF (Vect) switching <> Input SDI A Format AUTO 60.00) (1080i Int ×1.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.5.3 Color setting screen <> When the OVERLAY switch is held down in the VECTOR mode, the following settings can be performed. • Character color • Scale color • Vector color and brightness • Cursor color <> Input SDI A Format AUTO (1080i 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.6 STATUS mode 3.3.6.1 Normal screen <> The statuses can be displayed, and the following settings can be performed. • Status (numerical value) display • EAV, SAV display <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.6.2 Color setting screen <> When the OVERLAY switch is held down in the STATUS mode, the following settings can be performed. • Character color • Scale color • Status color • Cursor color <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.7 AUDIO mode 3.3.7.1 Normal screen <> The audio level meter is displayed, and the following function is provided. • Audio monitor display <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.7.2 Color setting screen <> When the OVERLAY switch is held down in the AUDIO mode, the following settings can be performed. • Character color • Scale color • Status color <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.8 MENU mode 3.3.8.1 Normal screen <> The menu screens can be displayed, and the following settings can be performed. • • • • • Format selection Reference setting Icon animation setting Error count resetting Initializing <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL [Description of operations] Switch FUNC switch Adjustment dial Setting switch F1 switch F2 switch F3 switch Animation F4 switch ErrorCount F5 switch AllInitialize Description of function (Not used) Use the dial to select the items to be set. Press this to select the format, set the reference or initialize the setting of the currently selected channel (reset to the CRC error count). Refer to section 4.6.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.8.2 Color setting screen <> When the OVERLAY switch is held down in the MENU mode, the following setting can be performed. • Character color <> Input SDI A Format AUTO 60.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 3.3.9 HELP mode <> The hierarchical levels of the modes and operation methods are displayed together. [Description of operations] Switch FUNC switch Adjustment dial Setting switch F1 switch F2 switch F3 switch F4 switch F5 switch Description of function (Not used) Used to scroll the pages. (Not used) (Not used) (Not used) (Not used) (Not used) (Not used) 3.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL CHAPTER 4 MAIN SPECIFICATIONS 4.1 Input formats Format Frame Rate (Hz) Active Line per Frame Total Line Per Frame Line Frequency (kHz) Samples per Active Line Samples per Total Line Scanning *1 *2 1035i/59.94 30/1.001 1035 1125 33.72 1920 2200 i 1035i/60 30 1035 1125 33.75 1920 2200 i 1080i/59.94 1080sF/29.97 30/1.001 1080 1125 33.72 1920 2200 i sF 1080i/60 1080sF/30 30 1080 1125 33.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 4.2 Input signal systems SDI input specification Specification HDTV SDI input BTA S-004B and SMPTE 292M standards complied with, NRZI SDI signal Field (frame) frequency, 60.00/59.94 [Hz], etc. automatically scanned Automatic scanning of input format enabled Analog input specification Specification BTA S-001B, SMPTE 274M and SMPTE 296M standards complied with HDTV YPbPr input Field frequency, 60.00/59.94 [Hz], etc.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 4.5 Concerning the adjustment values Brightness The offset level of the luminance signal can be varied in the range from -50.00 to +50.00%. Display level 100 +50% 0% -50% 0 Y gamma 100 Input level The Y gamma can be corrected in the range from 0.500-2.000; when 2.000 is exceeded, "Effect" results. Y gamma correction Display level 255 0.500 235 1.000 2.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL Contrast The level of the luminance signal can be varied in the range from 0.0-200.0%. Display level 100 Luminance signal level 200% 100% 50% Input level 0 Chroma, Pb (Cb), Pr (Cr) 0% 100 The level of the chrominance signals can be varied in the range from 0.0-200.0%.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 4.6 Settings at initialization The settings established when the WM-3004 was shipped from the factory or when they have been initialized are listed below. 4.6.1 Common setting items The settings for the following items are the same whether for the SDI A, SDI B or analog channels.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 4.6.2 Setting items by channel The following items are set separately for the SDI A, SDI B and analog channels. Setting item Bright Contrast Chroma Pb(Cb) Pr(Cr) Y Gamma Filter Mono FRC Green Blue Red Volume Output Information Color Marker Color Scale Color Waveform Color Cursor Color Vector Color Status Color Setting 0.00% 100.0% 100.0% 100.0% 100.0% 1.000 ON OFF OFF ON ON ON 128 L:1CH, R:2CH White3 White3 White1 Color15 Yellow2 Green16 White3 4.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 4.8 Outline drawings 2-1/4-20UNC, also provided on opposite panel A 105 105 SIGNAL SDI IN CH A Y IN SDI IN CH B PB IN 45 MONITOR OUT PR IN REF IN TALLY INPUT 37.9 Y PB PR 75Ω HIGH DC IN 12V ① GND ④ +12V MODEL ; SER.No ; MADE IN JAPAN 4-M4, also provided on opposite panel 26.5 38 INPUT F1 DISPLAY 2 3 1 2 AUDIO STATUS 80 PICTURE1 MENU OVERLAY F3 133 F2 A VECTOR WAVE FREEZE F4 FUNC LOCK F5 OFF ON POWER 26.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL CHAPTER 5 STANDARD AND OPTIONAL ACCESSORIES 5.1 Standard accessories WM-3004 instruction manual Rubber leg M4 screws (for attaching fixtures) AC/DC adapter 1 copy 4 pcs rack-mounting 4 pcs 1 pc (*1) 5.2 Optional accessories Provided for the WM-3004 as the optional accessories of the LCD unit (main unit) are rack-mounting fixtures, etc.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL NOTICE An incorrectly collated manual or a manual with missing pages will be replaced. All copyrights pertaining to this manual are the property of Astrodesign. This manual may not be used or copied in whole or in part without permission. The contents of this manual are subject to change without prior notice due to improvements. The manufacturer will not be liable for any outcome which results from the operation of the product.
WM-3004-HD HD LCD WAVEFORM MONITOR INSTRUCTION MANUAL 58