Instruction manual

Chapter 2 CONTROL METHODS (CONTROL MODES)
9
2.2.2 Control method
Set the signals of the EXT I/F connector as shown in the table below. For details on the connector
pin positions, refer to “4.2.2 EXT I/F connector” (on page 22); for details on the input levels, refer to
“4.1.2 EXT I/F” (on page 19).
Table Control method selected using the EXT I/F connector
Setting item Pin no. Setting *1 Description
111b Output port 1
110b Output port 2
101b Output port 3
100b Output port 4
011b Output port 5
010b Output port 6
001b Output port 7
Output port selection *2 3-1 (OUT_SEL[2-0])
000b Output port 8
1b Input port 1 Input port selection 6 (IN_SEL)
0b Input port 2
1b SELECTION mode *3 Output mode selection 7 (SW_DIV)
0b DISTRIBUTION mode *3
*1 At the “1” setting, input a high-level signal or leave the pin open; at the “0” setting,
input a low-level signal.
*2 When “SELECTION mode” has been set as the output mode, the TMDS, DDC and
CEC signals are all switched; when “DISTRIBUTION mode” has been set as the
output mode, only the DDC and CEC signals are switched.
*3 For further details on the SELECTION mode and DISTRIBUTION mode, refer to
“3.1 Output modes” (on page 15).
CAUTION