Wall outlets
GUT MMD 2 6S, MMD 2 12D, MMD 2 12E, MMD 2 14D
Multimedia broadband outlets
2 separate data connectors for direct connection of an interactive set-top-box resp. PVR
and cable modem
broadband layout of TV and RF frequency ranges
extremely high isolation between TV/RF and the data-ports for avoiding interference of
the SAT-IF
galvanic separation of the inner conductors of the TV-, RF- and data connectors to avoid
ripple voltage and stray electric current
screening according EN 50083-2 Class A
cover plate (80 x 80 mm) included
Type GUT MMD 2 6S
Order number 540121
EAN-Code 4026187131388
Stubline outlet
Tap loss
5 - 65 MHz: 66 - 83 MHz: 84 - 1000 MHz:
Data 1 [dB] 10,5 ± 1
Data 2 [dB] 10,5 ± 1
RF [dB] 50 typ. - 6,5 ± 1
TV [dB] 50 typ. - 6,5 ± 1
Isolation
5 - 65 MHz: 84 - 862 MHz: 862 - 1000 MHz:
Data 1 to RF [dB] ≥ 60 ≥ 30 ≥ 26
Data 1 to TV [dB] ≥ 60 ≥ 30 ≥ 26
Data 1 to Data 2 [dB] ≥ 38* ≥ 32 (470 - 862 MHz: ≥ 26) ≥ 24
Data 2 to RF [dB] ≥ 60 ≥ 30 ≥ 26
Data 2 to TV [dB] ≥ 60 ≥ 30 ≥ 26
TV to RF [dB] - ≥ 20 ≥ 20
Return loss
5 - 65 MHz: 66 - 83 MHz: 84 - 1000 MHz:
Data 1 [dB] ≥ 18 (-1,5 dB / Octave) F = 40 MHz
Data 2 [dB] ≥ 18 (-1,5 dB / Octave) F = 40 MHz
RF [dB]
≥ 14 (-1,5 dB / Octave)
(> 10 dB min.) F = 80 MHz
≥ 14 (-1,5 dB / Octave)
(> 10 dB min.) F = 80 MHz
TV [dB]
≥ 14 (-1,5 dB / Octave)
(> 10 dB min.) F = 80 MHz
≥ 14 (-1,5 dB / Octave)
(> 10 dB min.) F = 80 MHz
* between 5 and 15 MHz > 30 dB typ.