Datasheet

Universal broadband ampliers
151
Type HVF V38 P
Order number 217395
EAN-code 4026187120740
Connectors (75 Ω), Fuses* PG-11m - 3,5/12 F, G5x20
Forward path
Frequency range [MHz] 47 - 1006 or 5 - 65 / 80 - 1006 switchable
Gain [dB] 40 ± 1
Ripple [dB] ± 1
Output level [dBµV] 111 accord. EN80083-3 (see diagram), 60 dB CSO/CTB
Noise figure [dB] typ. 7**
Cable simulation in the input [dB] 0 to 10, pad, deemphase
Attenuator, input [dB] 0-20, pad
Interstage-attenuator [dB] 0 to 15, pad (see diagram)
Input equalizer [dB] 0 - 18, pad, preemphase
Interstage slope [dB] 0 or 6, switch, preemphase
Testpoints input / output [dB] bidirectional, 20 ± 2 / directional coupler 0 ± 1
Return path
Frequency range [MHz] 5 - 65, switchable
Gain [dB] 32 + 1
Output level [dBµV] acc. KDG: full load; acc. EN50083-3 IMA2 112; acc. EN 50083-5 KMA3: 117
Noise figure [dB] typ. 7 dB***
Attenuator [dB] 0 - 20, pad (input and output)
Output equalizer [dB] 0-18, pad, preemphase
Testpoints [dB] directional coupler, 20 ± 1 ( before controls), bidirectional, 20 ± 1 (behind controls)
Common data
Return loss [dB] ≥ 18 dB & at 40 MHz -1,5 dB/octave
max. remote current
incl. power consumption
[A~] 3 (through in- or output); 5 (through external power supply clamp)
Power consumption typ. [A] 0,75 / 24 V~; 0,45 / 40 V~; 0,32 / 65 V~
Remote powering voltage [V~] 24 to 65
Power consumption [VA] / [W] max. 18,5 / 13 with upstream; 10,5 without upstream
* Other connector and fuse types on request
** at 15 dB Interstage-attenuation typ.10,5 dB