Specifications

18
)../6!4)6%(%!24(02/$5#43s$)2%#46%.4'!3&)2%0,!#%3-ONTEBELLO$,8-ONTEBELLO$,8#$s).34!,,!4)/.).3425#4)/.3
./4%$)!'2!-3),,5342!4)/.3!2%./44/3#!,%
Horizontal terminations have been designed to perform in a wide range of weather condi-
tions. Our terminations meet or exceed industry standards.
When selecting the locations of your horizontal terminations, do not place the termination
where water from eaves and adjoining rooflines may create a heavy flow of cascading water
onto the termination cap. If the cap must be placed where the possibility of cascading water
exists, it is the responsibility of the builder to direct the water away from the termination cap
by using gutters or other means.
Take care to carefully follow the installation instructions for the termination, including the
use of silicone caulking where required.
Figure 27—Installing the Square Horizontal Termination (SV8HTS)
SV8HTS
Termination
Shown.
13 in.
(330mm)
8-1/2 in.
(216 mm)
(165 mm)
15 in.
(381 mm)
NOTE: Centerline of Vent Piping is NOT
the Same as the Centerline of the
Framed Opening.
6–48 in. Vent Section,
Telescopic vent section.
Base of Appliance
3 in.
(76 mm)
Adaptor
SV8RCH
1 in.
(25 mm)
1 in.
(25 mm)
6-1/2 in.
See other side for minimum
distance to base of appliance.
To help minimize water infiltration
install the Firestop/Spacer (SV4.5HF)
on the exterior side of the wall.
Figure 28—Wall Thickness and Horizontal Termination Requirements
For wall thicknesses greater than
8-1/2", see Table 9
Siding
Stucco
1-1/4” Maximum Recess of
Square Termination into
Exterior Finishing Material
Exterior Surface of
Framing
5” to 8-1/2”
(127 to 216 mm)
Exterior Surface of Siding
Minimum wall thickness
5” (127 mm)
Interior Surface of
Finished Wall
Maximum wall thickness
8-1/2” (216 mm)
SV8HTS
Square Termination
shown
Maximum Extent of Vent
Run Sections to Exterior
Surface of Framing
Last Vent Section. Use
Telescopic Vent Section
(SV8LA), If Necessary
Adaptor
SV8RCH
SV8HTS
Square Termination
Shown
Venting Connection and Exterior Wall Recessing
of the Horizontal Square Termination (SV8HTS).
See Figure 12 on Page 10 for Minimum
Distance to Base of Appliance
To help minimize water infiltration it
is recommended that the Firestop/
Spacer (SV4.5HF) be installed on the
exterior side of the wall.
J. Assemble vent run to exterior wall—If not
previously measured, locate the center of the
VENTATTHEEXTERIORWALL0REPAREANOPENINGAS
DESCRIBEDINStep B on Page 17!SSEMBLETHE
vent system to point where the terminus of the
LASTSECTIONISWITHINMMTO
MMINBOARDOFTHEEXTERIORSURFACETOWHICH
THE36(43TERMINATIONISTOBEATTACHEDSEE
Figure 29 and Table 9 on Page 19.
If the terminus of the last section is not within
this distance, use the telescopic vent section
SV8LA, ASTHELASTVENTSECTION&ORWALLTHICK-
nesses greater than that shown in Figure 28,
refer to Table 9 on Page 194HISTABLELISTS
THEADDITIONALVENTINGCOMPONENTSNEEDEDIN
ADDITIONTOTHETERMINATIONANDADAPTORFORA
PARTICULARRANGEOFWALLTHICKNESSES
K. Attach termination adaptor—Attach the
ADAPTORADAPTOR362#(PROVIDEDWITHTHE
TERMINATIONTOTHEVENTSECTIONORTELESCOPING
VENTSECTIONORELBOWASSHOWNINFigure 27
in the same manner as any SV vent component
REFERTOStep E on Page 17).
L. Install Firestop/Spacer at exterior wall
7HENUSINGTHESQUARE termination, install
36(&&IRESTOP3PACEROVERTHEOPENINGATTHE
EXTERIORSIDEOFTHEFRAMINGLONGSIDEUPWITH
THESPACERCLEARANCEATTHETOPASSHOWNIN
Figure 27, and nail into place.
4HE&IRESTOP3PACERMAYALSOBEINSTALLEDOVER
THEOPENINGATTHEINTERIORSIDEOFTHEFRAMING
M. Install the square termination (SV8HTS)
&OR THE LAST STEP FROM OUTSIDE THE EXTERIOR
wall, slide the collars of the termination onto
THEADAPTORTHEOUTEROVERTHEOUTERANDTHE
INNER INSIDE THE INNER UNTIL THE TERMINATION
SEATSAGAINSTTHEEXTERIORWALLSURFACETOWHICH
ITWILLBEATTACHED/RIENTTHEHOUSINGOFTHE
termination with the arrow pointed upwards.
3ECURETHETERMINATIONTOTHEEXTERIORWALLThe
horizontal termination must not be recessed
into the exterior wall or siding by more than
the 1-1/4" (32 mm) as shown in Figure 28.
IMPORTANT: The vent termination is hot
while in operation and for a period of time
following the use of the fireplace. Young
children should be carefully supervised
when they are in the same area as a hot
termination.