Technical data

DOC-01-TELAS-CRG-4 ASTi ACE Studio Components Reference Guide Rev.M
50 Copyright © 2014 Advanced Simulation Technology inc.
Pulse types 101 to 150 are called dwell1 to dwell 50. The spacing between pulses
(PRI) is modulated in a step like fashion. The length of time on each step is given
by the dwell time, and the number of steps is the dwell number plus one. (e.g., for
dwell5 there will be six steps.) The steps are evenly spaced, and the modulation
depth, as shown, gives their height.
The PRI time varies between
PRI Main x (1 - Modulation Depth)
and
PRI Main x (1 + Modulation Depth)
Figure 9: Dwell
The figure below shows the Random Dwell Pulse Type (Pulse types 151-199). The
random dwell is the same as the dwell, except that instead of stepping sequentially
through the levels it jumps randomly among them. The number of levels is given by
the Random Dwell number + 1 - i.e., Random Dwell 5 would jump through 6
different PRI modulation times.
In addition, there is a Random Dwell with no number (Pulse type 199). With this
pulse type, the PRI time jumps randomly throughout it's allowed range, staying at
each PRI time for a dwell time.
The allowed range for the random dwell is between
PRI Main x (1 - Modulation Depth)
and
PRI Main x (1 + Modulation Depth)
Figure 10: Random Dwell