Technical data

DOC-01-TELAS-CRG-4 ASTi ACE Studio Components Reference Guide Rev.M
48 Copyright © 2014 Advanced Simulation Technology inc.
Internal Parameters
PlayAll
Type Default Value
boolean False
Description: This parameter is used in one-shot mode. In normal
mode, if the step count is toggled from 0 to a non-zero value and
back to zero, the pulses will stop playing immediately when the Step
Count goes back to zero. In Play All mode, the pulses will finish
playing to the end of the sequence.
Step Mode
Type Default Value
pulse_step_mode fixed
Description: This parameter determines whether the pulse durations
are given in absolute times in microseconds (fixed mode) or as a
fraction of the loop time (fractional mode).
When the loop time is modulated, fractional mode causes the pulses
to shorten and lengthen in proportion to the loop time. In fixed
mode, the pulses remain at their fixed durations when the loop time
is varied. If the loop time becomes less then the sum of the pulse
durations in fixed mode, the end pulses will get cut off.