Technical data

ASTi ACE Studio Components Reference Guide Rev. M DOC-01-TELAS-CRG-4
Copyright © 2014 Advanced Simulation Technology inc. 227
Command List
* Refer to the URC-200 operator manual for specifics on these commands.
Command Name Command Code
Zap Z
Set Squelch $
Set Preset P
Set Frequency R
Set Transmit Frequency T
Set Modulation Mode M
Set Tx Modulation Mode N
Set Text Mode X
Store Preset Q
Set Power Level #
Set Beacon Mode *
Set Keypad Control +
Set Transmit Mode B
Set Receive Mode E
Synth Lock/Unlock ?01
Receive Sig Strength ?03
SW Version ?08
Squelch Level Setting ?09
Current Preset Status ?10
Text Mode Status ?11
General Status ?11
General Mode Status ?12
Squelch Status ?13
Control Inputs
Control
Enable
Type Default Value
boolean True
Description: When TRUE the remote control function is enabled
and control messages should be passing between the ACE-RIU and
the live radio.
Load
Preset
Type Default Value
boolean True
Description: When TRUE the component will only attempt to load
presets and will not attempt to modify preset settings. Preset set-
tings are Frequency, Tx Frequency, Modulation Mode, Tx Modula-
tion Mode, Power Level, and Text Mode. As a consequence of this,
the ‘Result’ column of these settings (in the RCU section) will be
overridden by the live radio’s current setting.
Store
Preset
Type Default Value
boolean False
Description: Triggers a ‘Store Preset’ command on the remote
radio, saving the current preset’s state to the radio’s internal
memory. Refer to the radio’s operator manual for more information.
The save command will be sent when this control is initially set to
TRUE from a FALSE state.
External
PTT
Type Default Value
boolean False
Description: When TRUE the control message exchange between
the ACE-RIU and live radio are halted. It might be useful to have
this TRUE when the live radio is transmitting, so that the radio is
not simultaneously transmitting and processing remote control
messages, as this might cause excessive noise on the transmitted
signal.