Technical data
ASTi ACE Studio Components Reference Guide Rev. M DOC-01-TELAS-CRG-4
Copyright © 2014 Advanced Simulation Technology inc. 214
Control Inputs
TxEnable
Type Default Value
boolean True
Description: Defaults to True. If True then transmit is enabled for
the Transceiver.
Audio Outputs
RxAudio
Type Default Value
audio n/a
Description: The Transceiver local audio receive audio stream, i.e.
this is the receiving audio the Transceiver will pickup from in-tune
transmitting radios.
TxCrypto-
Audio
Type Default Value
audio n/a
Description: The audio the crypto tones player generates for trans-
mit states only.
Control Outputs
Jammed
Type Default Value
boolean False
Description: Indicates whether the Transceiver is being jammed or
not.
Control Outputs
Range
Type Default Value
float32 0.0
Description: The distance to the transmitter currently being
received in meters.
RxActive
Type Default Value
boolean False
Description: Indicates whether the Transceiver is receiving.
RxAudio-
Active
Type Default Value
boolean False
Description: When True the Transceiver receive output is non-zero.
True if squelch is broken or audio is received.
RxCrypt
Type Default Value
boolean False
Description: True when the radio is actively receiving a secure
transmission.
RxData-
Dropped
Type Default Value
int32 0
Description: The number of data packets that the radio detected
coming from an intune transmitting radio when RxDataThreshold-
Met was False and therefore were not forwarded to the local host.