Technical data
ASTi ACE Studio Components Reference Guide Rev. M DOC-01-TELAS-CRG-4
Copyright © 2014 Advanced Simulation Technology inc. 193
Control Inputs
Interval1
Type Default Value
basic/uint16 0
Description: Used to set the delay between repeating the keyed
word when number is set to 1. Units are in seconds.
Interval2
Type Default Value
basic/uint16 1
Description: Used to set the delay between repeating the keyed
word when number is set to 2. Units are in seconds.
Interval3
Type Default Value
basic/uint16 0
Description: Used to set the delay between repeating the keyed
word when number is set to 3. Units are in seconds.
Interval4
Type Default Value
basic/uint16 1
Description: Used to set the delay between repeating the keyed
word when number is set to 4. Units are in seconds.
Interval5
Type Default Value
basic/uint16 1
Description: Used to set the delay between repeating the keyed
word when number is set to 5. Units are in seconds.
Control Inputs
Interval6
Type Default Value
basic/uint16 1
Description: Used to set the delay between repeating the keyed
word when number is set to 6. Units are in seconds.
Interval7
Type Default Value
basic/uint16 1
Description: Used to set the delay between repeating the keyed
word when number is set to 7. Units are in seconds.
Interval8
Type Default Value
basic/uint16 1
Description: Used to set the delay between repeating the keyed
word when number is set to 8. Units are in seconds.
IdentIndex
Type Default Value
basic/uint8 0
Description: Selects which marker beacon (IdentChar or word) is to
be transmitted. A value of 0 selects none. A value of 1 selects
Ident1Char[0-3] (the Outer Marker). A value of 2 selects the second
word (Middle Marker). A value of 3 selects the third word (Inner
Marker). A Value of 4 selects the fourth word (Fan Marker).