Technical data

DOC-01-TELAS-CRG-4 ASTi ACE Studio Components Reference Guide Rev.M
8 Copyright © 2014 Advanced Simulation Technology inc.
Tips
The 3 dB tolerances are adjustable to be tighter or looser depending on the
requirements and what needs to be proved.
The purpose of the /tmp/autodred.dat file is that it provides easier viewing of
all the data. The same signal levels are shown in the component data viewer.
Distance above noise floor is only shown in the file.
The background noise test (test 5) can be useful, but it should only fail if
there is a drastic change in background noise level. In the Mathplan tables
for levels and thresholds, the background noise test is the first entry in the
“5” column. To start, set a larger threshold, perhaps 6 dB.
This TableXY should be populated with the measured RMS signal level for each
speaker, for each test. These levels should be copied from the /tmp/autodred.dat file
following a setup run.
Enter failure thresholds (in dB) into this TableXY for each speaker, for each test.
The AutoDRED test will fail if one of the measured signal levels differs from the
reference levels by more than the specified failure threshold.
Audio Inputs
InSignal
Type Default Value
audio n/a
Description: Audio stream input links. All of the incoming audio is
mixed in this component.