Technical data

ASTi Telestra 4 Target Operations & Maintenance Manual (Ver. 1, Rev. K)
20 Copyright © 2013 Advanced Simulation Technology inc.
Objects lists the number of transmitter and entity objects on the HLA network. For trans-
mitters, the local counter reflects the number of local transmitter objects while the rti
counter reflects the number of remote objects. For entities, the local counter reflects the
number of entities the federate has detected on the HLA network. The attached counter
reflects the number of local radios that are attached to existing entities.
BYE
This command can be entered at any time to gracefully leave the HLA federate application. If
joined, the Target will not resign before exiting.
DEBUG {value}
This command can be entered at any time and is used to display or set the current debug level.
If the command is entered without a value it will display the current debug level. If entered
with a level that debug level will be set.
The debug level parameter determines which combination of debug messages are printed to
the file. The value is derived from a debug mask described in the following table.
Remote Control Debug Levels
Level Debug Mask Position Description
0 Off
1 General (required to print any debug
me
ssages)
2 RTI Object Activity
4 New Ethernet Object Info
8 Name Information
16 Ethernet Activity
32 RTI Activity
64 Handle
128 Translate
256 Timeouts
512 Convert
1024 Context
For example, to log “Name Info”, you would set the debug level to 9, which is 8 (Name Info)
plus 1 (turn logging on). Setting the debug level to 8 would not work, because it represents 8
(Name Information) plus 0 (logging off).
If you wanted to log “RTI Object Activity”, “New Ethernet Object Info”, “Ethernet Activity”,
and “RTI Activity”, but NOT “Name Info”, you would set the debug level to 55 (32 + 16 + 4