4.5 AC AND DMX WIRING
AC power and DMX data can be connected to the Titan Tube via Astera’s PowerBox (FP1-
PWB) and Astera’s power/data combination cable (FP1-PWB-CAB). That way, the tubes can
be wired for a longer show or permanent installation.
The PowerBox contains Neutrik True1 Powercon in and out sockets and 5-pin XLR in and out
sockets so that several PowerBoxes can be daisy chained. In addition, data can also be
applied to the PowerBox via its RJ45 Ethernet socket which accepts Art-Net DHCP, 2.X and
10.X as well as sACN. Its operation is explained in the next chapter.
The PowerBox has 10 DC sockets to wire 10 TitanTubes via power/data combination cables
(sold separately, item code: FP1PWBCAB5, -10. -15). 10 output means that a whole DMX
universe of tubes can be connected (10 tubes x 16 pixels x 3 channels).
Power Data
(Powercon True1) (5-pin XLR)
10 x Power/Data
combination cable