Specifications
CL33700 PWI/PIP Series Cylindrical Lock
9
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
7. Install Spring Cassette and Route Wires:
a. Plug harness into wire from lock body (Fig. 7a, b).
b. Route lock body harness and ground wire (Fig. 7b Detail).
c. Install inside spring cassette, and tighten using two #12-24
screws provided (Fig. 7a).
d. Run wires through slots in edges of spring cassette (Fig. 7b)
Note: Do not run wires through center hole and be careful
not to pinch wires under spring cassette.
There are DOOR EDGE markings on the
cassette for orientation.
Wire Routing: This image shows wood door prep,
with wire run channel in inside face of door.
Door Status
Switch
Fig. 6a
6. Install Lock:
a. Feed lock body and wires through 2-1/8” diameter hole from outside
of door (Fig. 6a).
b. Be sure latch engages lock body (Fig. 6b).
IMPORTANT: Door must remain open during installation. Use door stop.
Fig. 6b
Fig. 7b Detail
Ground Screw
Wire Harness
Connector
and Wire
Ground Wire
Fig. 7a
Alternate construction would be a raceway through
the door core.