Specifications
CL33700 PWI/PIP Series Cylindrical Lock
8
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
5. Install Door Status Switch supplied with product:
a. Drill 3/4” hole in frame for switch (Fig. 5a and 5b).
b. Snap the sensor in place in the frame.
c. Insert connector end of DPS harness through raceway on
latch edge of door (Fig. 5c).
Note: Use collar in METAL door only.
d. Push door status switch firmly into place by hand.
Important: DO NOT TAP SWITCH WITH ANY TOOL.
Horizontal
of Strike
Door Status
Switch Hole
Vertical
of Strike
Dim 2
(See template)
Dim 1
Fig. 5b
Wood Frame Metal Frame
Dim 1
3/8” 3/4”
Strike for Cylindrical Lock
Door
Status
Switch
McKinney
Electronic
Transfer
Hinge
(if PoE)
CL33700 PWI/PIP
Series Lock
Patent Pending
Fig. 5a
Door Status Switch
Fig. 5c
Collar is used only
with metal doors.
Inside of Door