Specifications
CL33700 PWI/PIP Series Cylindrical Lock
12
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
Fig. 10
Access Gasket
Outside Access Trim
11. Install (optional) Weatherseal Gasket:
For non-fire rated door applications, an optional gasket may
be used as a weatherseal between the escutcheon and
the outside door surface.
Peel off the adhesive backing on the gasket and
install the gasket along the edge of the outside
escutcheon assembly (Fig. 10).
Fig. 11b
DPS
Reader Cable
Mounting Plate
Position ground
ring terminal
upright, then
tighten screw.
Lock body cable
a. Insert the mounting posts through holes as shown (Fig. 10).
b. On the inside of the door, align mounting plate with
indicated holes (Fig. 11a).
c. Feed reader cable through central opening in mounting
plate (Fig. 11a).
d. Lockbody cable feeds from bottom (Fig. 11a and 11b).
e. Make sure they are positioned upright (Fig. 11a).
f. Insert other three #8-32 x 1-7/8” flat head machine screws and
tighten, fastening the outside escutcheon to the door (Fig. 11a).
12. Install Outside Escutcheon
Inside Face of Door
Fig. 11a
(4) #8 - 32 x 1-7/8” Flat
Head Machine Screws
Mounting Plate
(2) #8 - 3/8” flat head
Wood Screws