Specifications

CL33700 PWI/PIP Series Cylindrical Lock
10
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Fig. 8
8. Connect cables:
Connectors go on one way. Each connector is
mated to prevent connecting incorrectly.
a. Connect 2-pin wire to Door Status Switch.
b. Connect 4-pin connector from harness into
wire from lock body.
c. Install the rose over the inside cassette.
5) Installation Instructions (Continued)
9. Installation and Removal of Lever and Standard Cylinders:
Inside Face of Door
(2) #12-24 Screws
Spring Cassette
Inside Rose
Harness