700 TCPWI1/TCPIP1 ™ Installation Instructions CL33700 TCPWI1 & TCPIP1Series Cylindrical Lockset FM323 3/14 Attention Installer Please read these instructions carefully to prevent missing important steps. Please Note: Improper installations may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock. Misalignment can cause premature wear and a lessening of security.
CL33700 PWI/PIP Series Cylindrical Lock Table of Contents 1) Warning.................................................................................2 2) General Description..............................................................3 3) Specifications / Features.....................................................3 4) Product Illustration..............................................................4 5) Installation Instructions.......................................................
CL33700 PWI/PIP Series Cylindrical Lock 2) General Description Designed specifically for the campus market, the Corbin Russwin Access 700 series mortise Locks are available in WiFi (PWI) and PoE (PIP) configurations. Coupled with third party software the PWI and PIP offers a complete, integrated access control system. The Access 700 may be used for both indoor and outdoor applications (weather-protective gasket supplied).
CL33700 PWI/PIP Series Cylindrical Lock 4) Product Illustration 5 4 1 2 3 6 ITEM No. PART No. DESCRIPTION 1 784F565 FIN Outside Escutcheon Assembly, Mag Swipe 784F575 FIN Outside Escutcheon Assemby, Mag Swipe and Keypad 784585 FIN Outside Escutcheon Assemby, Mag Swipe, Keypad, HID 125kHz Prox, and 13.56 MHz Prox 784595 FIN Outside Escutcheon Assemby, Mag Swipe, HID 125kHz Prox, and 13.56 MHz Prox 784F605 FIN Outside Escutcheon Assemby, Mag Swipe, Keypad, HID 125kHz Prox, and 13.
CL33700 PWI/PIP Series Cylindrical Lock 4) Product Illustration (Continued) Tools Required: • Phillips Screw Driver #2, #3 • Flat Blade Screw Driver (Standard size) • 1/8” Security Allen Wrench (supplied • 7/64” Allen Wrench (supplied) • T20 Security torx driver (supplied) 4 2 3 1 1 2 3 4 783F918 CL33134 Cylindrical lock with fixed core cylinder 1 783F928 CL33134 Cylindrical lock with removable core cylinder 1 784F118 Inside Spring Cassette - REX (D134) 1 784F128 Inside Spring Cassette
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions 1. Verify Hand and Bevel of door: Illustrations shown are as viewed from the outside or secure side of opening. Left Hand Hinges Left. Open Inward. “LH” 2. Left Hand Reverse Bevel Hinges Left. Open Outward “LHRB” Right Hand Hinges Right. Open Inward. “RH” Right Hand Reverse Bevel Hinges Right. Open Outward “RHRB” Prep door according to supplied Door Marker (FM302). For door manufacturer templates visit www.corbinrusswin.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 3. Install Latch Bolt: Install using two #8 x 3/4” combination screws (Fig. 3). Note: Make sure the beveled bolt is facing the strike. Fig. 3 4. Install Strike: Install using two #12 x 1” combination screws (Fig. 4). Centerline of Latch Front and Strike Optional Strike Box Fig. 4 Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 5. Install Door Status Switch supplied with product: a. Drill 3/4” hole in frame for switch (Fig. 5a and 5b). b. Snap the sensor in place in the frame. c. Insert connector end of DPS harness through raceway on latch edge of door (Fig. 5c). Note: Use collar in METAL door only. d. Push door status switch firmly into place by hand. Important: DO NOT TAP SWITCH WITH ANY TOOL.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 6. Install Lock: a. Feed lock body and wires through 2-1/8” diameter hole from outside of door (Fig. 6a). b. Be sure latch engages lock body (Fig. 6b). Door Status Switch IMPORTANT: Door must remain open during installation. Use door stop. Fig. 6b 7. Install Spring Cassette and Route Wires: a. Plug harness into wire from lock body (Fig. 7a, b). b. Route lock body harness and ground wire (Fig. 7b Detail). c.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 8. Connect cables: Inside Face of Door Connectors go on one way. Each connector is mated to prevent connecting incorrectly. a. Connect 2-pin wire to Door Status Switch. Harness b. Connect 4-pin connector from harness into wire from lock body. c. Install the rose over the inside cassette. Spring Cassette (2) #12-24 Screws Fig. 8 9.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 9. Installation and Removal of Lever and Standard Cylinders (continued): Standard Cylinder Installation Make sure cylinder tailpiece is aligned in same direction as cylinder bible. Slide cylinder all the way into the lever. For 6-pin cylinder: Fold retainer at hinge and press fit retainer halves together as shown. For 7-pin cylinder: Break retrainer at hinge and discard spacer section.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 11. Install (optional) Weatherseal Gasket: For non-fire rated door applications, an optional gasket may be used as a weatherseal between the escutcheon and the outside door surface. Peel off the adhesive backing on the gasket and install the gasket along the edge of the outside escutcheon assembly (Fig. 10). 12. Access Gasket Outside Access Trim Install Outside Escutcheon a.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 11. Installation of Connectors CAUTION - Do not touch or allow debris to enter connector contacts. Reader (24-pin) DPS (4-pin) 9-24VDC Power* Secure the following connectors to their respective terminals (Fig. 12a, b ): a. Secure the 2-pin DPS connector. b. Secure the 10-pin lock body assembly connector. *NOTE: Optional 2-pin external 9-24VDC power connector. Board-to-Board Connector B A Lock Body (10-pin) C Fig.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) a. Insert bottom tab of controller into slot on mounting plate (Fig. 12a, b). b. Looking down from top of controller, ensure proper alignment of board-to-board connectors (Fig. 12b) while pivoting controller toward door until two tabs on top snap securely into place on mounting plate (Fig. 12b). CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate.
CL33700 PWI/PIP Series Cylindrical Lock 5) Installation Instructions (Continued) 13. Battery Installation Before installing batteries for the first time: Remove pull tab from its position beneath the coin cell by pulling on tab in direction of arrows printed on tab (Fig. 13). a. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly. b. After batteries are installed, there is a slight delay; then an audible “beep” will sound and the lock motor will cycle.
CL33700 PWI/PIP Series Cylindrical Lock Important Note: Wiring Installation If you are installing PIP (PoE) please go to Page 17 PIP Installation Wiring If you are installing PWI please go to Page 20 Operational Check Continue With Installation... Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
CL33700 PWI/PIP Series Cylindrical Lock 6) PIP (PoE) Installation Wiring 17. PIP (PoE) Installation Wiring: Frame harness assembly AA. PoE (From McKinney) Door harness* CC. PoE (From McKinney) data hinge (Patent Pending) BB. PoE (From McKinney) 700 PIP (PoE Lock) DD. Access * Order of installation may vary. Refer to appropriate sections for instructions.
CL33700 PWI/PIP Series Cylindrical Lock 6) PIP (PoE) Installation Wiring (Continued) Frame Harness Installation A Supplied by CI Components and wire harness supplied by McKinney: Suggested installation.
CL33700 PWI/PIP Series Cylindrical Lock 6) PIP (PoE) Installation Wiring (Continued) C Hinge Installation Order of installation may vary. Refer to appropriate sections for instructions. Hinge-side harness connectors: • 4-pin male Molex connector • 6-pin male Molex connector with ground wire Lock-side harness connectors: • Ring terminal • (2) 4-pin connectors: • 4-pin Molex connector • 4-pin connector Notes: • Connectors go on only one way. They cannot be plugged to incorrect position.
CL33700 PWI/PIP Series Cylindrical Lock 6) Operationial Check IMPORTANT: Be sure to test functions prior to closing door. In all cases, perform the following checks: 1. Ensure that inside lever retracts latch (and deadbolt for deadbolt functions). • For units with cylinders, the following checks apply: Insert key into cylinder and rotate a. There should be no friction against lock case, wire harness, or any other obstructions.
700 TCPWI1/TPIP ™ Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.