User's Manual

Table Of Contents
ACGPass e-ID Desktop Reader, Ver. Dual ISO 2.3
8.4.4.2.2 Decrement failure 'F'
The Decrement failure indicates a general failure during the decrement procedure or
inability to read after the write process.
8.4.4.2.3 No tag error 'N'
The reader does not detect a response from the tag. There is either no tag present or
the tag does not respond to the request.
8.4.4.2.4 Operation mode failure 'O'
The tag is not ISO14443 type A compliant.
8.4.4.3 Copy value block (backup)
Copies a value block to another block of the same sector. A read is done
automatically after the write to ensure data integrity. Used for backup and error
recovery. A previous login is needed to access a block.
Command
Command Data
'=' Source block (1 byte)
Target block (1 byte)
Answer
Answer Description
Data New value of target block (4 bytes).
'I' Error: value block failure
'F' Error: increment failure
'N' Error: No tag in field
'O' Error: Operation mode failure
Example
Command Description
=0405 Copy value block 4 to block 5
=0506 Copy value block 5 to block 6
ASSA ABLOY Identification Technologies GmbH 85