User's Manual

Table Of Contents
ACGPass e-ID Desktop Reader, Ver. Dual ISO 2.3
8.4.3.15.2 No tag in field 'N'
The tag does not respond. There is either no tag present or addressed.
8.4.3.15.3 Operation mode failure 'O'
The presented tag is not ISO14443 type A compliant.
8.4.3.15.4 Out of range failure 'R'
The block address of the 'r' command is higher than 40h.
The block address of the 'r' command conflicts with other commands, therefore the
block address has to be limited to 40h.
Use the 'rb' command instead.
8.4.3.16 Read reader EEPROM
This command reads the internal reader EEPROM. It contains all start-up parameters
and the device ID. Changes in the start-up settings will only go into effect after a
reset of the device.
Command
Command Data
'rp' EEPROM address (1 byte) 00h … EFh
Answer
Answer Description
Data EEPROM data (1 byte)
'R' Error: Out of range failure
Example
Command Description
rp0B Reads protocol configuration register.
8.4.3.16.1 Out of range failure 'R'
The entered EEPROM address is not valid.
ASSA ABLOY Identification Technologies GmbH 74