8.4.3.5.3 Answer from 0xh and 1xh
The lower nibble contains the baud rate used for the air interface.
Baud Rate Description
x0 106kBaud
x2 212kBaud
x4 424kBaud
x8 848kBaud
Figure 8-21: Baud Rate values
The higher nibble contains the frame size used for the air interface.
Frame Size Description
0x 16 Bytes
1x 24 Bytes
2x 32 Bytes
3x 40 Bytes
4x 48 Bytes
5x 64 Bytes
6x 96 Bytes
7x 128 Bytes
8x 256 Bytes
Figure 8-22: Frame Size
8.4.3.5.4 Answer from 2xh and 3xh
The option byte is returned as the answer.
8.4.3.5.5 Select a single tag
No previous continuous read is required. The command executes an automatic field
reset.
8.4.3.5.6 Extended ID
See above for more information on Extended ID.
The RATS answer is inserted between the serial number and baud rate / frame size
byte for ISO14443 A tags.