User's Manual

Table Of Contents
ACGPass e-ID Desktop Reader, Ver. Dual ISO 2.3
8.3.4.5 LED (default 0)
If set the reader suppresses any LED activity. The user manages the state of the
LEDs.
8.3.4.6 Single shot (default 0)
If set, the reader displays the serial number of a tag in continuous read mode once
within a specified time-out. The time-out is defined at EEPROM register 0Fh.
The delay time can be adjusted stepwise in 100ms steps. 00h indicates no delay and
FFh indicates infinite delay.
8.3.4.7 Extended Protocol (default 1)
If set, the transfer data telegram command supports ISO14443-4.
The transfer data telegram command is only supported in normal mode, not in
transmit / receive mode.
ASSA ABLOY Identification Technologies GmbH 40