8.4.6.25.1 Our of range 'R'
If sent data exceeds the maximum of 232 bytes, the error R ('Out of range') is
returned.
Note
If performance is important 232 bytes should be used for plain data and 224 should
be used for enciphered and MACed data, because in this case the smaller frames
from the DESFire tag are filled up completely.
8.4.6.26 Get Value
This command reads a value block of a selected value file.
Command
Command Data
17h None
Answer
Answer Description
00h +
Value (4 bytes)
Value
'C' Error: CRC or MAC does not match
'N' Error: No tag in field
'O' Error: No file selected
Xxh DESFire status / error code, refer to DESFire
documentation
Example
Command Description
f0117 Answer: 0022222222
value 22222222h is currently stored in the value
file.