User's Manual

HF Mifare Easy Module V1.0
ACG Identification Technologies GmbH 55
7.4.3.18.4 Writing values
The write value block command is designed to create blocks, which match the value
format. This command requires write access to specified block. It is not
recommended to use this instruction for ticketing operations. For ticketing
applications special instructions (Increment/Decrement/Copy) are supported.
7.4.3.19 Reset
This command executes a power on (software) reset. New configuration settings will
be loaded. It resets all tags in the antenna field.
Command
Command Data
'x' None
Answer
Answer Description
'Mifare 1.0' + <CR> + <LF> ASCII Mode
None Binary Mode
7.4.3.19.1 Reset Timing
The power up timing depends on environmental conditions such as voltage ramp up.
For handheld devices the timing can change on the charging state of the battery.