ACG Identification Technologies GmbH 29
7.3.5 BAUD, Baud rate control register (06h)
The baud rate register defines the communication speed of the reader device.
Default value is 00h.
Baud rate register
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
RFU RFU RFU RFU RFU RFU BS1 BS0
Figure 7-5: Baud rate register
This register defines the baud rate of the device.
BS1 BS0 Baud rate
0 0 9600 baud (default)
0 1 19200 baud
1 0 38400 baud
1 1 57600 baud
Figure 7-6: Baud rate settings
Following figure describes the communication settings
Description
8 data bits
No parity bit
1 stop bit
No flow control
Figure 7-7: Communication settings
7.3.6 Reset Off Time (07h)
The Reset Off Time register represents the field off time in ms.
This register is used for the select, continuous read and multi tag commands.
Default value is 10h.