User's Manual

HF Mifare Easy Module V1.0
ACG Identification Technologies GmbH 27
7.3.3 StationID (04h)
The station ID is used in binary mode to address a device in party line set up. The
station ID has the range of 01h to FEh and can be set freely. The value 00h is
reserved for the bus master. All readers send their response to this device.
The broadcast message (FFh) forces all readers to response to the command.
Default value is 01h.
7.3.4 Protocol configuration (05h)
The protocol configuration register (PCON) specifies general behavior of the reader
device.
Default value is 01h.
Protocol configuration register
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
RFU RFU RFU Multitag
Binary
Timeout
Extend
ID
Binary Auto
Start
Figure 7-4: Protocol configuration register
7.3.4.1 Autostart (default 1)
If set the reader device will start up in continuous read mode automatically.
7.3.4.2 Protocol (default 0)
If set the reader uses binary protocol mode. Refer to binary protocol for further
information on the binary protocol format.
Default setting = ASCII protocol (0).