ACG Identification Technologies GmbH 86
12.4.3.18.4 Out of range failure 'R'
The block address of the 'r' command is higher than 40h.
The block address of the 'r' command conflicts with other commands, therefore the
block address has to be limited to 40h.
Use the 'rb' command instead.
12.4.3.19 Read reader EEPROM
This command reads the internal reader EEPROM. It contains all start-up parameters
and the device ID. Changes in the start-up settings will only go into effect after a
reset of the device.
Command
Command Data
'rp' EEPROM address (1 byte) 00h … EFh
Answer
Answer Description
Data EEPROM data (1 byte)
'R' Error: Out of range failure
Example
Command Description
rp0B Reads protocol configuration register.
12.4.3.19.1 Out of range failure 'R'
The entered EEPROM address is not valid.