User's Manual

ACG HF Multi ISO RFID Reader V1.0
ACG Identification Technologies GmbH 54
12.3.9.2 Disable start-up message (default 0)
If Disable start-up message is set, the reader suppresses the start-up message in
ASCII mode. This flag is ignored in binary protocol mode.
12.3.9.3 Enable binary frame v2 (default 0)
If Enable binary frame v2 is set, the reader sends version 2 binary frames.
The get station ID command always sends version 1 binary frames!
12.3.9.4 Noisy Environment (default 0)
If Noisy Environment is set, the continuous read mode can only be aborted with the '.'
character. When working in a noisy environment, the probability for a reception of an
arbitrary/stochastic signal is quite high. This implies a high probability of an
unintentional command execution. To reduce this probability, only one character (out
of 255) is chosen (‘.’) to be interpreted as the continuous read stop command.
12.3.9.5 Reset Recovery Time Multiplier (default 0)
Multiplies the Reset Recovery Time, including the recovery time of the field reset
command.
Reset Recovery Time Multiplier Reset Recovery Time
0 1x
1 2x
2 3x
3 4x
Figure 12-15: Reset Recovery Time Multiplier
12.3.9.6 Enable ISO14443 B Anti-collision (default 0)
If set, the anti-collision algorithm for ISO 14443 B tags is enabled.
12.3.9.7 Disable ISO 14443-4 Error Handling (default 0)
If Disable ISO 14443-4 Error Handling is set, ISO14443-4 Error Handling is disabled.
The error handling always uses the TMR time-out.
12.3.10 Reset Off Time (14h)
The Reset Off Time register represents the field off time in ms.
This register is used for the select, continuous read and multi-tag commands.
Default value is 0Ah.