User's Manual Part 1

13,56 MHz Multitag Reader Module, Version 0.9v
ACG Identification Technologies AT Page 43
6 Timing
The timing is measured between request and response of the reader. Additionally to
the process timing the protocol timing must be included. It depends on protocol mode
as well as on the baud rate.
Time
Fail
Time
Typ
Time
Max
Command
[ms] [ms] [ms]
Reset
5
Power up - 80,0 85,0
Software (x) - 2,98 3,06
Get version (v) - 0,206 -
Continuous read (c)
6
All - 13,6 164,0
ISO 15693 - 13,6 14,1
Tagit - 20,4 21,0
Icode - 31,0 32,0
SR176 - 26,4 54,0
ISO 14443 Type A - 18,0 19,0
Ultralight - 26,0 27,0
ISO 14443 Type B - 14,8 15,5
Page read (start up option)
All - 22,4 105,0
ISO 15693 - 22,4 23,6
Tagit - 37,6 38,0
Icode - 37,2 38,0
Select (s)
All 392,0 20,5 392,0
ISO 15693 50,8 20,5 21,0
Tagit 81,6 20,4 21,0
Icode 116,0 31,0 32,0
SR176 54,8 26,4 54,0
ISO 14443 Type A 43,8 18,0 19,0
Ultralight 43,8 26,0 27,0
5
Reset will cause an error if reader IC Initialization fails
6
Continuous read will only return successful readings