5.3.17.6.2 Command code
Refer to ISO15693-3 or the tag manufacturer documentation for more details.
5.3.17.6.3 UID
The UID is optional. If address flag is set it is mandatory. Only the addressed VICC
executes the command. All other tags remain quit.
5.3.17.6.4 Data
Depends on command code.
5.3.17.7 Answer
The length of the answer is specified in the uplink length byte. Following figure shows
a complete response data frame.
Flags Data CRC
(1 byte) (n byte) (2 bytes)
Figure 5-21: ISO15693 response format
If the less bytes are send from the card than specified in the length byte following
bytes are even displayed:
Byte 1 Byte 2 - up to length bytes
80h 00h
Figure 5-22: ISO15693 response trailer
5.3.17.7.1 Response flags
Bit Flag name Value Description
0 No error 0 Error
1 Error is thrown
1,2,3,
4,5,6,
7
RFU 0 Reserved for future use
Figure 5-23: ISO15693 response flags
5.3.17.7.2 Error
If the error flag is set the VICC has generated an error. Next byte contains the error
code. Refer to the card manufacturer documentation for specific details of the error.
5.3.17.8 Example
Command Description
T030A270100 000066554433221100E0
Inventory response of card
E000112233445566