C) Multi-node telemetry. In this application the rover receives remote uncorrected pressure and
temperature from multiple bases using a mesh network topology. The pressure data is absolute
and not differentially corrected.
Specifications
Differential Pressure Accuracy: +/- 0.028 mbar (+/- 25cm) RMS
Absolute Pressure Accuracy: +/- 2 mbar
Temperature Accuracy: +/- 1 C
Operating Temperature: -20C to 70C
Current: 20-120mA peak @ 5VDC (DBO433/DBO915), 20-130mA peak @ 5VDC (DBO868)
Dimensions (L x W x H): 82mm x 32mm x 18mm
Range: 1Km* (DBO433/DBO915), 5Km* (DBO868)
Voltage: 3.8 – 15 VDC
Weight: 30g
* In mode C above individual bases act as mesh network repeaters when in range of any others
potentially increasing totals beyond these specifications.
Pinout
Pin
Description
ROVER
Rover mode jumper selection
BASE
BAT+
Battery supply (3.8
15 VDC)
GND
Ground
RXD
Serial data in
TXD
Serial data out
DTR/RTS
Serial flow control
Serial communication parameters are 9600bps (N,8,1). The DTR/RTS signal pin is only required
to update the firmware.