Operation Manual
C
ALIBRATING
THE
EF1210
WITH
EFP
ANEL
C
ONTROL
S
OFTWARE
ASPI Digital -
The Sound of DSP
Technical Support: 404.892.3200 A-7
C
ALIBRATING
THE
EF1210
WITH
EFP
ANEL
C
ONTROL
S
OFTWARE
If you would like to exit Setup mode at any time, click on the Cancel button. All
original settings before you entered Setup will be restored.
As you calibrate the EF1210, you can use the EF1210 Calibration S
TEP
I
NDICATOR
on
the EFPanel Toolbar (see Figure 22 on page 5) to help keep track of which calibra-
tion mode you are in.
To Start EF1210
Calibration
Click on the Setup button (see Figure 22 on page 5) to enter configuration mode of
the EF1210.
C
ALIBRATION
S
TEP
1: C
ALIBRATING
M
ICROPHONE
I
NPUT
C
HANNELS
For Calibration Step 1, the S
TEP
I
NDICATOR
will be lit in the first position.
i. Select pink noise output source. This is the Zone that will output pink noise for
microphone calibration.
Note.
To calibrate the EF1210 using the EFPanel control software, you
need to be able to see the EF1210 front panel LED meters.
Figure 23.
Calibration Step 1: Calibrating Microphone Inputs