Operation Manual

EF1210 U
SER
M
ANUAL
78 http://www.aspi.com Copyright © 1999, All Rights Reserved
SELECTI
N
-
SET
FRONT
PANEL
INPUT
METER
TO
DISPLAY
INPUT
CHANNEL
N
The SELECTI
n
command sets the front panel I
NPUT
meter to display input channel n
of the EF1210.
The factory default setting for SELECTIn is 1 (input channel 1).
Remote Commands
The following commands can be sent by the remote control device to set the front
panel I
NPUT
meter to display input channel n.l
EF1210 Messages
The following messages are sent by the EF1210 in response to a SELECTI? com-
mand, or in response to any SELECTI
n
command when acknowledgment mode is
on.
Example
In the following example, the remote control device requests the current channel dis-
played on the I
NPUT
meter of the EF1210 with Device ID number 7. Then it sets
channel 5 to be displayed on the I
NPUT
meter of the same EF1210. Acknowledgment
mode is enabled.
Remote Command Effects
SELECTI
n
Set front panel I
NPUT
meter to display input chan-
nel n.
n ranges from 1 to 8.
SELECTI? Request current assignment of front panel I
NPUT
meter.
EF1210 Message Message meaning
SELECTIn Front panel I
NPUT
meter is currently set to display
input channel n.
Remote Command EF1210 Message
C07SELECTI? C07SELECTI1
C07SELECTI5 C07SELECTI5