Operation Manual

EF1210 U
SER
M
ANUAL
6 http://www.aspi.com Copyright © 1999, All Rights Reserved
Q
UICK
I
NSTALLATION
Installation of the EF1210 involves two procedures: hardware installation, and cali-
bration.
H
ARDWARE
I
NSTALLATION
Hardware installation involves the following steps:
1. Set rear panel DIP switches to select Line or Mic level and enable phantom
power for each microphone input channel, and to select ASPI Bus Device ID if
necessary. See “Configuration” on page 15.
2. Connect input and output signals (See “Connecting the EF1210 to other equip-
ment” on page 19):
Connect the 8 Mic/Line Inputs to microphones.
Connect the 8 Line Outputs to the inputs of a mixer.
Turn off Phantom Power on automixer.
Connect Zone Output(s) to amplifier(s) or powered loudspeaker(s).
Connect AEC Reference Inputs to the T
O
AEC output of an EF200 or to the
output of a CODEC.
If you wish to use the EF1210’s built in Playback/Record mixer feature, con-
nect A
MIX
I
N
, A
UX
I
N
, T
O
CODEC, and R
EC
as directed in “Playback/
Record” on page 22.
3. If you are using an RS232 remote control device, connect it to the RS-232
R
EMOTE
C
ONTROL
port; if you are controlling multiple ASPI devices, connect
them using the ASPI Bus ports (See “Connecting the ASPI Bus” on page 26).
4. Connect the external power supply.
C
ALIBRATION
Calibration of the EF1210 involves a sequence of five calibration steps to configure
the input and output levels of the EF1210 to match those of the equipment to which it
is connected. The EF1210 can be calibrated either from the front panel or by using a
computer. Please refer to “Calibration” on page 27 for more detailed information on
the Calibration procedure. Correct calibration is essential for satisfactory operation of
the EF1210, so please take the time to familiarize yourself with the details of the Cal-
ibration procedure by reading “Calibration” on page 27.
For front panel calibration, enter Calibration mode by pressing and holding the A
UX
I
N
L
EVEL
/S
ETUP
and I
NPUT
S
ELECT
front panel buttons for 2 seconds. In Calibration
mode, the S
ETUP
LED will blink to let you know which setup step you are currently
executing. Press the A
UX
I
N
L
EVEL
/S
ETUP
button to move from one Calibration step
to the next. When you have finished Calibration step 5, press the A
UX
I
N
L
EVEL
/
S
ETUP
button again to exit Calibration mode; any changes that you made will be
saved as the default power-on settings when you exit the Calibration procedure.
Caution!
The EF1210 is designed to maintain a 1/4” (6.35 mm) air circula-
tion clearance above the enclosure. Do not stack or install
EF1210s in such a way as to defeat this clearance, block the side
vent holes, or otherwise impede air circulation around the
EF1210.