Operation Manual

EF1210 U
SER
M
ANUAL
62 http://www.aspi.com Copyright © 1999, All Rights Reserved
GAINC -
SET
CODEC
OUTPUT
GAIN
The GAINC command sets the CODEC output gain level of the EF1210 to a level
between 0 dB and 20 dB. The output gain setting corresponds to a nominal output
level that ranges from -20 dBu to 0 dBu, respectively.
The factory default setting for GAINC is 12 (-8 dBu = -10 dBV).
Remote Commands
The following commands can be sent by the remote control device to set the CODEC
output gain level.
EF1210 Messages
The following messages are sent by the EF1210 in response to a GAINC? command,
or in response to any GAINC command when acknowledgment mode is on.
Example
In the following example, the remote control device requests the current CODEC out-
put gain of the EF1210 with Device ID number 7. Then it sets a new level on the
same EF1210. Acknowledgment mode is enabled.
Remote Command Effects
GAINCx Set CODEC output gain.
x ranges from 0 dB to 20 dB.
GAINC? Request current CODEC output gain.
EF1210 Message Message meaning
GAINCx CODEC output gain is currently x dB.
Remote Command EF1210 Message
C07GAINC? C07GAINC0
C07GAINC4 C07GAINC4