Operation Manual

EF1210 C
OMMAND
S
ET
R
EFERENCE
ASPI Digital - The Sound of DSP Technical Support: 404.892.3200 55
V
ALID
C
OMMANDS
AND
M
ESSAGES
The following table is a list of commands recognized by the EF1210.
The following table is a list of messages sent by the EF1210 to the host.
Table 5: EF1210 Command List
Command Meaning Page
ACKMOD enable/disable acknowledgment mode 56
AEC
n
enable/disable acoustic echo canceller on channel n 58
AECS
n
set suppression mode on channel n.59
ERROR enable/disable error messages 61
GAINC set CODEC output gain 62
GAINI
n
set M
IC
/L
INE
input gain on channel n 63
GAINP set playback input gain (on A
UX
I
N
input) 65
GAINR
c
set R
EFERENCE
input gain on reference c 66
GAINZ
c
set Z
ONE
output gain on output c 68
LOCKFP lock front panel (disables front panel buttons) 69
MUTEI
n
enable/disable mute on M
IC
input channel n 70
NC
n
enable/disable noise cancellation on channel n 71
NCL
n
set noise cancellation level on channel n 72
PING see what devices are connected to the remote controller 73
REFASGN
nc
assign reference c to input channel n
RESETF restore settings to factory default 75
RESTNV
m
restore settings from non-volatile memory in memory
slot m
76
SAVENV
m
save current settings to non-volatile memory in mem-
ory slot m
77
SELECTI
n
set front panel input meter to display input channel n 78
SELECTR
c
set front panel remote meter to display remote input
channel c
79
SR change the sample rate of the EF1210 80
SWVER request software version 81
Table 6: EF1210 Message List
Message Meaning Page
ERROR# error condition occurred 82
PONG device response to PING command 83