Operation Manual
C
ALIBRATING
THE
EF1210
WITH
EFP
ANEL
C
ONTROL
S
OFTWARE
ASPI Digital - The Sound of DSP Technical Support: 404.892.3200 A-13
other Reference in step i.
v. Once the AEC Reference Inputs have been calibrated, click on the Next button
to proceed to Playback/Record calibration.
C
ALIBRATION
S
TEP
4: C
ALIBRATING
FOR
P
LAYBACK
AND
R
ECORD
For Calibration Step 4, the S
TEP
I
NDICATOR
will be lit in the fourth position. This
step calibrates the T
O
CODEC signal. No other calibration is necessary for Playback/
Record.
The T
O
CODEC signal may be adjusted to match the level required by your CODEC
(or other remote terminal equipment) input.
Caution!
If you skip this calibration step, you will compromise the
performance of the EF1210. The audio coming from or
going to the remote end may be too low, so if you turn up
the loudspeaker to compensate, the acoustic gain will be
affected.
Note.
You may skip this step if you are not using playback and record on
the EF1210.
Figure 26. Step 4: Calibrating for playback and record.