User manual
MEX ASPERA-3
Ref.:
ME-ASP-MA-0002
Issue:
Issue 1 Rev. 4
Date:
15/2/2002
Page:
Page 13 of 58
ASPERA-3 EGSE User Manual
IFSI
CNR
File location: /Mex/powConvrc Link to
/users/cerulli/cpp/scoe/scoe/ powConvrc
#####################################
# Power conversion configuration file
#####################################
#
# The conversion is X= AY + B with
# Y=byte/word value, X=value in engineering unit
# In this file are the A and B coefficients for the various
# tabbed panels in the Status/HK windows
# Power panel (astatus7)
[Power]
#-------- I30
AI30=0.1176
BI30=0.0
#-------- I5
AI5=0.0196
BI5=0.0
#-------- VM12
AVM12=-0.047
BVM12=0.0
#-------- VM5
AVM5=-0.0196
BVM5=0.0
#-------- V5
AV5=0.0196
BV5=0.0
#-------- V12
AV12=0.047
BV12=0.0
#-------- V30
AV30=0.1176
BV30=0.0
#------- Scanner panel
[ScanPos]
#------- pos to degree conversion (astatus6)
ADEG=0.772
BDEG=0.0
File location: /Mex/mexiltrc Link to
/users/cerulli/cpp/mexilt/mexilt/mexiltrc
# mexilt Configuration file File
[String]
#-------- TM archive directory
FILARCH=/Mex/scArch/
#-------- Socket server
SERVERHOST=127.0.0.1
[IntConst]
#-------- Socket port number
PORT=6010
#-------- timeout for requested ack
ACKATIMOUT=20