User's Manual
Table Of Contents
- Important Safety Instructions
- Welcome to Hydrasynth!
- Quick Start Guide
- Overview
- Hydrasynth Desktop
- Understanding the Modules
- The Oscillator Group
- The Mixer Module
- The Filters and their Controls
- The Amp Module
- The Envelopes
- The LFOs
- The Effects
- The Voice Module
- Ribbon Controller (keyboard only)
- The Arpeggiator Section
- Mastering the Macros
- The Mod Matrix
- The CV / Gate Section
- Patch Management
- The System Setup Pages
- Control Combinations
- Scales
- Hydrasynth Specifications
- Declaration of Conformity
41
Set the Pan Positions
Osc 1-3 Pan
To set the stereo placement of the oscillators, access [MIXER] and use the Page Down arrow
to select page 2. In the top row are the pan positions for Oscillators 1-3. Use the appropriate
Control knob to adjust the pan position of each item, and use [SHIFT] + Control knob X to
ne-tune the value.
Ring + Noise Pan
To set the stereo placement of the Ring modulator and Noise generator, access [MIXER] and
press the Page Down arrow twice to select page 3. In the top row are the parameters Ring Pan
and Noiz Pan. Use the appropriate Control knob to adjust the pan position of each item, and
use [SHIFT] + Control knob X to ne-tune the value.
Filter Routing of Sources
Osc 1-3 Filter routing
To adjust the routing of each oscillator between Filter 1 and Filter 2, access [MIXER] and use the
Page Down arrow to select page 2. In the bottom row are the lter routing values for Oscillators
1-3. Use the appropriate Control knob to adjust the lter routing of each item:
• 100:0 sends the source only to Filter 1.
• 0:100 sends the source only to Filter 2.
• Intermediate values send the source to both lters in varying amounts.
Use [SHIFT] + Control knob X to ne-tune the values.
Ring + Noise Filter routing
To adjust the routing of the Ring modulator and Noise generator between Filter 1 and Filter 2,
access [MIXER] and press the Page Down arrow twice to select page 3. In the bottom row are
the lter routing parameters RingFilt and NoizFilt. Use the appropriate Control knob to adjust
the lter routing of each item:
• 100:0 sends the source only to Filter 1.
• 0:100 sends the source only to Filter 2.
• Intermediate values send the source to both lters in varying amounts.
Use [SHIFT] + Control knob X to ne-tune the values.
Filter Configuration
This setting species whether the lters operate in Series or Parallel mode. When they are in
Series, Filter 1 always passes through Filter 2. When they are in Parallel, sources can be routed
so they pass through only one of the lters or through both lters in varying amounts (as
described above in Filter Routing of Sources (p.41)).
The setting is linked to Filter 1 page 2, edit eld 1; changing one also changes the other.