User's Manual
Table Of Contents
- Important Safety Instructions
- Welcome to Hydrasynth!
- Quick Start Guide
- Overview
- Hydrasynth Desktop
- Understanding the Modules
- The Oscillator Group
- The Mixer Module
- The Filters and their Controls
- The Amp Module
- The Envelopes
- The LFOs
- The Effects
- The Voice Module
- Ribbon Controller (keyboard only)
- The Arpeggiator Section
- Mastering the Macros
- The Mod Matrix
- The CV / Gate Section
- Patch Management
- The System Setup Pages
- Control Combinations
- Scales
- Hydrasynth Specifications
- Declaration of Conformity
25
Changing the Pad Key
We’ll describe this rst before getting into the Pad Modes. In addition to selecting scales and
Pad Modes it’s also possible to dene the root key for the pads. The default key is C, but you can
choose any note in the chromatic scale. The process is simple:
1. Hold [SHIFT] through the nal step.
2. Press the top-row pad labeled [KEY]. The Left display shows the current Pad Key. The bottom
two rows of pads show colors representing a single chromatic octave: yellow = the current root
note (C), blue = white keys, green = black keys, grey = inactive.
C# D# F# G# A#
C D E F G A B C
3. Select pad 10 to change the Pad Key. The Left display shows Pad Key = C#.
4. Release [SHIFT]. Pads 1-24 now begin on a C# in the lower left corner and work their way
upward according to the scale and Pad Mode settings. This is a global setting; it aects all
presets.
Note that the next time you repeat this process, pad 10 will be yellow in step 2 above since the
Pad Key has been changed to C#.
C# D# F# G# A#
C D E F G A B C
The Pad Key setting does not transpose
incoming MIDI note data.
Pad response options
Velocity and pressure
The velocity- and pressure sensitivity of the pads can be toggled on and o independently.
These parameters are found on page 3 of the Keys / Pads: Page 3 (p.86).
Sustain
Use [SHIFT] + [LATCH] to toggle the Sustain function on and o if you don’t have a sustain pedal
connected.